Rolling steel garage doors.
Metal fire door specification.
Backbend return face stop soffit rabbet throat.
Hinges all fire doors must be hung on three steel hinges to resist bowing in the.
Labeled fire doors control the spread of fire and smoke for up to 3 hours.
Sdi tests steel doors and frames for strength quality consistency security weather and fire resistance wear and tear and longevity.
Protection association for fire doors and fire windows nfpa 80 and the door components installation instructions.
Terminology used in describing these frames follows as closely as possible the american national standard for nomenclature for steel doors and steel door frames ansi a250 7.
Steel is the sole door material to deliver a 3.
Fire rated steel doors play a vital role in keeping people safe and minimizing property damage during a fire.
Our promise is to deliver affordable owner friendly rolling steel doors that are reliable architecturally pleasing and simple to maintain.
Standard steel doors and frames sdi 118 2012 basic fire door fire door frame transom sidelight frame and window frame requirements sdi 124 2016 maintenance of standard steel doors and frames sdi 134 14 glossary of terms for hollow metal doors and frames 2 21 ansi standards ansi ul 10b standard for fire tests of door.
All values which do not carry specific tolerances or are not marked maximum or minimum shall have the following tolerances.
For difficult non standard door openings blanks can be purchased and cut down.
Where required by a manufacturer s listing or ansi nfpa 80 fire doors and fire windows a steel overlapping astragal shall be provided.
2 1 2 3 steel astragals on fire doors.
2 1 2 4 louvers for fire doors.
Metal fire doors are an economical alternative to wood fire doors when more than a 20 minute rating is required.
This guide specification addresses the requirements for hollow metal doors frames and related products and reflects the growing choices of steel door and frame constructions available.
The following is a list of the current technical documents available from the steel door institute.
This specification has been prepared in accordance with the csi recommended master format.
Linear dimensions shall be 1 16 in.
In most cases standard fire doors can be adjusted to fit normal door opening sizes.
When specified fire doors shall be provided with fire labeled louvers.
Testing is undertaken in conjunction with the top testing labs in the country like ul intertek national fire protection association nfpa american national standards institute ansi and american society.
This is an example of a section 081113 hollow metal doors and frames specification for a healthcare facility which includes standard doors and frames fire rated assemblies sidelights and more.